KwikDraw Gas Detector Tubes for Carbon Monoxide, 0.1 – 1.0 Vol%, 10 Per Box – D5085822
Application
Detection of carbon monoxide (CO) in air or in technical gases.
Detector Tube Sampling Pump
KWIK DRAW(formerly MSA AUER) Gas-Tester® IIH, Gas-Tester® I / ThumbPump™-Sampler, Toximeter® II, Uniphos Kwik-Draw™-Pump or other suitable detector tubes pumps. Observe respective instructions for use.
Measuring Range
0.1 vol.% … 1.0 vol.% carbon monoxide at n=1 (1 stroke).
Chemical Reaction and Color Change
Oxidation of carbon monoxide by iodine pentoxide in fuming sulfuric acid.
Color change: White/yellowish → Brown
Interferences and Cross Sensitivities
a) No interference from:
– Hydrogen, methane, ethane, carbon dioxide, as well in concentrations above 50 vol.%.
– sulfur dioxide, nitrogen dioxide, propane up to 1 vol.%.
– Higher saturated hydrocarbons (e.g. hexanes, octanes), olefinic hydrocarbons (e.g. ethylene) up to 200 ppm.
b) Interfering concentrations of hydrocarbons may be eliminated by adding a charcoal filter tube Ads (804403).